Cert library.

Every cert held in the Crateworks supply network. NFRC across the window and door line, Miami-Dade NOA on the hurricane impact configurations, CSA A440-22 for cold climates, AAMA 2605 finish, STC 56 acoustic, and NAFS CW-PG50 on sliding and bifold doors. Cert IDs disclosed on every quote.

Posture: cert held in the Crateworks supply network. Specific cert-holder identity is confirmed in writing at project-quote stage.

Energy + thermal performance

  • NFRC certification

    Applies to: Casement, tilt-turn, fixed/picture, awning, arc-top, sliding, bifold, single-hung, double-hung, storefront window wall

    The National Fenestration Rating Council operates the only US energy-performance rating program for windows, doors, and skylights. NFRC ratings cover U-factor, solar heat gain, visible transmittance, air leakage, and condensation resistance.

  • US Energy Star

    Applies to: Bifold doors

    US EPA Energy Star Most Efficient program for fenestration. The bifold configuration is registered for the current cycle.

  • CSA A440-22 cold-climate

    Applies to: Casement, tilt-turn, fixed, awning, sliding, bifold, swing

    Canadian Standards Association harmonized fenestration standard. Covers U-factor, air-water-structural performance, and cold-climate suitability. U-factor range on file: 0.236 to 0.387 depending on configuration.

Hurricane impact + HVHZ

  • Miami-Dade NOA (Awning)

    Applies to: Awning windows for Florida HVHZ

    Notice of Acceptance from the Miami-Dade County Building Code Compliance Office. Large Missile + Small Missile impact rated for Florida High Velocity Hurricane Zones. Approval number and documents are on your quote.

  • Hurricane impact line (Crateworks supply network)

    Applies to: Awning, casement, fixed/picture, single-hung, sliding door, sliding window, bifold, storefront window wall, storefront door

    These configurations carry hurricane impact certification within the Crateworks supply network. Florida HVHZ coastal projects ship from this line; cert IDs disclosed on quote.

  • Hurricane impact test cert

    Applies to: Awning + sliding + bifold

    Hurricane impact tested. Cert paired with NFRC NOA for FL HVHZ project specification.

Air + water + structural

  • NAFS CW-PG50: Sliding doors

    Applies to: Sliding doors up to 4500mm panel

    North American Fenestration Standard performance grade. CW = Commercial Window, PG50 = performance grade 50. Sliding doors tested to CW-PG50 by the manufacturer, up to 4500mm panel.

  • NAFS CW-PG50: Bifold doors

    Applies to: Bifold doors

    North American Fenestration Standard performance grade for bifold configuration.

Finish + acoustic

  • AAMA 2605 PVDF coating

    Applies to: All aluminum window + door frames

    American Architectural Manufacturers Association voluntary performance specification for high-performance organic coatings on architectural aluminum extrusions and panels. Two-stage polyvinylidene fluoride coating. 20-year finish warranty on file.

  • STC 56 acoustic

    Applies to: Acoustic configurations available across the window line

    Sound Transmission Class 56 measured per ASTM E90 (laboratory method). STC 56 corresponds to a high-performance acoustic glazing build; specify acoustic at quote.


How we cite a cert.

Every quote names the certification and the configuration it covers. Where a cert is held within the Crateworks supply network, the PDF ships with the project submittal for your architect and code official.

Bigger project? Book a call.

Spec the project and we will return the matching cert PDFs with the quote. Send a project brief or visit the trade program.