- Rough-in is the pipework that goes in before the walls close: water supplies, drains and vents, each placed for a fixture you already chose.
- A concealed shower valve body, a wall-mount faucet body and a conventional wall-hung toilet's carrier go into the wall itself, so they have to be decided, and some on site, before rough-in.
- Toilet rough-in is the distance from the finished wall to the centre of the drain. Twelve inches is the North American standard.
- The code's rough inspection happens before anything is covered. Fixtures arrive about 90 days, delivered, so send the schedule with your rough-in date at least that far ahead.
What does it mean when a bathroom is roughed in?
It means the plumbing is in, but nothing is finished. Supply lines are stubbed out and capped where each faucet, valve and toilet will connect. Drains are set where each fixture will empty, and vents tie them into the system. The walls are still open studs.
Every one of those openings is placed for a specific fixture. A vanity drain sits where that vanity's basin will drop. A toilet drain sits at the distance that toilet was built for. Change the fixture after the walls close and the pipes are in the wrong place.
So the hard part of rough-in is not the plumbing. Your plumber knows how to rough in a bathroom. What they need from you is the list of what goes where, early.
What is included in bathroom rough in plumbing?
Three things, for every fixture: the water supply (hot and cold lines to each faucet, valve and toilet), the drain (a trap and a line sized for that fixture), and the vent that keeps the trap working.
Drain sizes follow the fixture. Under the International Residential Code (the model code most US states adopt; your town may amend it), a bathroom sink trap is 1 1/4 inch and a bathtub trap is 1 1/2 inch. A shower trap is 1 1/2 inch up to 5.7 gallons per minute of total flow, and 2 inch above that, up to 12.3 gallons per minute.
That shower line is where your selections touch the drain. The code counts a hand shower as a shower head, so every outlet adds to the total. A rain head, a hand shower and body sprays together can push the drain up a size. Settle the shower before the drain is set. Our post on shower valve rough-in covers what goes in that wall.
Vents have limits too. The same code caps the distance from a 1 1/4 inch trap to its vent at 5 feet, and from a 1 1/2 inch trap at 6 feet. That is one reason moving a vanity along the wall after rough-in is more than a small change.
Seen from the bathroom door, looking into the corner, with the two near walls and the drywall taken away.
- Goes in before drywall
- The fixture you see later
- Cut open to show inside
- Shower valve body, fixed in the wall before board and tile, with a line up to each outlet: here the overhead shower and the hand shower.
- Shower drain in the floor, at least 1 1/2 in.
- Toilet drain in the floor, 12 in out from the finished wall on most toilets. Your toilet's own sheet decides.
- Toilet water line, with the smart toilet's outlet planned on the wall behind the toilet at the same time.
- Vanity drain and the hot and cold lines, set to the heights on your vanity's rough-in sheet.
- Floor-mount tub filler: the plumber places its supply at rough-in.
Which fixtures have to be chosen before rough-in?
Anything with a part inside the wall, or a pipe at a position only that model needs. Here is the list, one line each.
A concealed shower system: the valve body goes in at rough-in, before the wall is boarded and tiled. It has to be on site, not just chosen.
A wall-mount bathroom faucet: its in-wall body is placed at rough-in, before tile. A deck-mount goes through the counter instead; pick single-hole or two- or three-hole before the counter is cut.
A freestanding tub filler: floor-mount for a tub set away from the wall, wall-mount where one side of the tub is against a wall. Decide before rough-in so the plumber can place the supply and, on designs that have one, the body set in place at rough-in.
A floating vanity: the drain and supply stubs sit at the vanity's bottom height, not the usual floor-level positions, and the vanity hangs on blocking inside the wall. Our post on bathroom sink drain height walks through the numbers.
A conventional wall-hung toilet: the bowl cantilevers off an in-wall carrier and the tank hides inside the wall, so the carrier is set during framing. Some wall-hung models, like our wall-hung smart toilet, have the tank built in and mount on a load-bearing wall bracket instead.
A smart toilet: ours runs on 120V power, so its outlet is planned at rough-in, with the water line. Our post on the GFCI outlet for a bidet covers what to tell your electrician.
A hardwired heated towel rack: the supply hides in the wall, so the decision belongs at electrical rough-in, not at fit-out.

Do I need a 10 inch or 12 inch rough in the toilet?
Toilet rough-in is the distance from the finished wall to the centre of the floor drain. Twelve inches is the North American standard, and most toilets are roughed in at 12 inches. Ten and fourteen inch rough-ins exist and are common in older houses and tight powder rooms. In a new build, the drain goes wherever the toilet you chose needs it, so the answer is the number on that toilet's install sheet.
One detail catches people. The 12 inches is measured from the finished wall, so with 1/2 inch drywall the flange centre ends up 12 1/2 inches from the framing. Choose the toilet first, confirm its toilet rough-in, and check whether it drains through the floor or the wall. The wrong rough-in is not a fixable problem at install.
What does the plumbing rough in inspection check?
The International Residential Code requires a rough inspection of plumbing, mechanical, gas and electrical work before anything is covered or concealed, before fixtures are set, and before the framing inspection. Ask your builder when it is booked.
The inspector checks the work against the code your area adopted. Checking it against your own selections is what your walkthrough is for: our pre-drywall inspection checklist lists what to look at in each bathroom.
When should you order bathroom fixtures?
Work back from the rough-in date. Crateworks fixtures are made to order and delivered in about 90 days, so send the schedule with your rough-in date at least that far ahead. A concealed valve body that arrives after the walls close means opening the wall or changing the plan.
The bathroom list is due before rough-in, not at fit-out. Builders say late selections are where cost jumps come from. Settle the bathroom list first and the rest of the schedule has room to move.
One quote can cover the whole bath list: faucets, shower systems, tub fillers, accessories, toilets, basins, tubs and vanities, in one finish through the house. Your licensed plumber installs it.
Decide before rough-in, fixture by fixture.
| Fixture | What to decide | Why it is locked at rough-in | Our page to read |
|---|---|---|---|
| Concealed shower system | Concealed or exposed; how many outlets | The valve body goes in the wall before it is boarded and tiled. More outlets can mean a bigger drain | Shower systems |
| Bathroom faucet | Wall-mount or deck-mount; single-hole or two- or three-hole | A wall-mount body is placed at rough-in, before tile. Hole count is set before the counter is cut | Bathroom faucets |
| Tub filler | Floor-mount or wall-mount | The plumber places the supply, and on some designs a body, at rough-in | Tub fillers |
| Toilet | Rough-in distance; floor or wall drain; floor-standing or wall-hung | The drain is set at one distance from the finished wall. A conventional wall-hung carrier goes in during framing | Toilets |
| Smart toilet | The model | Ours runs on 120V power, so the outlet is planned at rough-in with the water line | Smart toilets |
| Floating vanity | The model and its mounting height | Drain and supply stubs sit at the vanity's bottom height, and it hangs on blocking in the wall | Floating vanities |
| Heated towel rack | Hardwired or plug-in | A hardwired rack's supply hides in the wall, so it is set at electrical rough-in | Towel warmers |
Common questions.
- What does a roughed in bathroom look like?
- Open stud walls with the pipes in place and capped. You see supply stubs where each faucet, valve and toilet will connect, drain openings in the floor and wall, and vent pipes running up. If there is a concealed shower system, its valve body is already fixed in the wall.
- What is the meaning of plumbing rough in?
- Rough-in is the stage when supply, drain and vent pipes are installed in open walls and floors, before drywall and before any fixture is set. Finish plumbing comes later, when the faucets, shower trim, toilets and basins are connected to those pipes.
- How do you rough in the plumbing for a bathroom?
- Your licensed plumber does the work. Your part is the fixture list: each model and the install sheet that comes with it, so drains, supplies and valve bodies go in at the right positions. Send that list with your rough-in date.
- Can you change a fixture after rough-in?
- Sometimes, but it costs time. A drain or supply in the wrong place means opening walls or floors, and a concealed shower valve has to be in before the wall is boarded. The toilet is the hard one: the bowl has to match the drain, and the wrong rough-in cannot be fixed at install.
- When does a concealed shower valve need to be on site?
- At plumbing rough-in, before the wall is boarded. Lead time is about 90 days, delivered, so send the schedule with your rough-in date at least that far ahead.
Sources.
- International Residential Code 2021, Table P3201.7 (trap sizes), state-adopted text on UpCodes
- International Residential Code 2021, Table P3105.1 (trap to vent distance), state-adopted text on UpCodes
- International Residential Code 2021, Table P2903.2 (hand showers count as shower heads), state-adopted text on UpCodes
- International Residential Code 2021, Section R109.1.2 (rough inspection), state-adopted text on UpCodes
- Fine Homebuilding, Installing a Toilet (toilet rough-in from the finished wall)
Bathroom build checklist
Step 6 of 11
Choose
Measure
Rough-in
- 06Bathroom Rough-In Plumbing: What to Decide First
- 07Shower Valve Rough-In for a Concealed Shower
- 08Bathroom Sink Drain Height and Vanity Rough-In
- 09Wall-Hung Toilet Carrier: What Goes in the Wall
- 10GFCI Outlet for a Bidet or Smart Toilet: Where It Goes
Inspect
Keep reading.
Get a quote
Have drawings or a builder's quote?
Send them. We price the same spec, line by line, so you can compare it with what you have. Your builder stays in charge of the job.
Send your plansOnly have the bathroom?
Send a photo and the measurements, including the distance from the wall to the drain. It comes back priced as one bath package.
Start with the bathroomBuilder or contractor?
Trade partners get a written schedule guarantee, Partner Credit on annual spend and pricing locked to delivery.
See trade termsSchedule terms
Price your bath list before rough-in
Send the fixture list with your rough-in date. Every line is quoted separately and delivered in about 90 days.